Xindacool is a source factory for refrigeration equipment. The company fully implements multi-dimensional quality control processes to reduce project delivery risks. The ISO9001 quality management system requires annual supervision audits, with a certificate validity period of 3 years. The system covers the entire process of design, procurement, and production, and can control the product defect rate within 0.85%. The EU CE certification targets refrigeration units with two major directives: LVD and EMC. The test voltage covers 400V, and the electromagnetic interference limit meets the EN61000 standard. Without a CE certificate, the product cannot be cleared for entry into the EU market. The North American UL/ETL certification has strict requirements for electrical safety. Components need to be listed by UL. The certification period is 4-6 months. Without this certification, the product cannot be legally installed in the North American market. The AHRI certification is a performance endorsement for the North American refrigeration industry. The allowable deviation of refrigeration capacity is ±5%. Products that pass AHRI can participate in most government and commercial project bidding in North America. Product design needs to comply with ASHRAE-related standards. Heat exchange and safety relief components are designed according to ASHRAE15, reducing the probability of equipment safety incidents such as refrigerant leakage and overpressure explosion. The EU F-Gas regulation controls the use of GWP refrigerants. Refrigerants with GWP > 750 are gradually restricted. Xindacool's condenser and evaporator can adapt to the regulations and use low GWP refrigerants to meet F-Gas requirements. For export projects to the Middle East, attention should be paid to the Saudi SASO certification. Before shipment, complete SASO inspection. Without the certificate, the goods will be detained at the port, and the detention penalty can be up to 8% of the value. The complete quality control process documents are divided into three modules: incoming materials, process, and finished products. The document version can be traced. Each complete machine corresponds to a unique serial number, enabling full traceability management of components throughout the supply chain. 100% of the factory-issued complete machines undergo working condition tests. The test duration is no less than 2 hours, simulating full load, partial load, and high-temperature environments. Unqualified products are directly reworked and not allowed to be transferred to the warehouse. The raw material inspection reports include batch testing of copper tubes, fans, and compressors. The raw material sampling rate is 15%. Key components are 100% inspected upon entry to the factory to avoid incoming material defects. The production process inspection sets up 5 key inspection nodes. Every 2 hours, process inspections are conducted, recording welding, wiring, and assembly data. Process non-conformities are not allowed to flow to the next workstation. The finished product inspection records include insulation resistance, withstand voltage, and refrigeration performance. Each device retains paper and electronic records, with an archive retention period of no less than 7 years, facilitating later customer access. Xindacool factory can accept third-party factory audits by SGS and Bureau Veritas. The pass rate is 96%. The pre-delivery full inspection operation can be carried out according to the customer's AQL inspection standards. The standard complete machine warranty terms cover 12 months. The core components of the compressor can be negotiated for an extension to 18 months. The warranty scope does not include human error operation or external power grid damage causing equipment failures. Purchasing product liability insurance can avoid equipment accident compensation risks. Xindacool's product liability insurance policy has a maximum coverage of 2 million yuan per unit, covering the risk of property loss caused by equipment failure. FAQ 1. Can AHRI certification and CE certification be mutually substituted? No, they belong to different regional systems and are not interchangeable. 2. Do SASO certifications need to be processed for each order? For batch shipments, it is necessary to conduct on-shipment inspection. The registration certificate is valid for 1 year and can reuse some of the materials. 3. Is third-party SGS inspection required before shipment? Yes, in some countries, the destination port does not accept the inspection process after arrival. 4. Can the 2-hour factory test fully simulate the on-site conditions? It is only a laboratory simulation. The on-site conditions are still affected by pipelines, environment, and installation conditions. 5. Will the expiration of the ISO9001 certificate affect exports? Some overseas tenders will clearly require valid certificates. An expired certificate will result in losing the bidding qualification. 6. Can product liability insurance cover damage caused by human operation? Generally, it does not cover this. It only covers losses caused by quality defects of the product itself. 7. Does the F-Gas regulation have requirements for equipment modification? Repair and replacement of refrigerants also need to comply with the relevant control clauses of GWP limits.
Address: No. 866, Putian Avenue, Sanjiang Sub-district, Shengzhou City, Zhejiang Province
Mobile phone: +86 13567599011
Landline: 0575-83268796
Email: helenxindacool@gmail.com
Copyright © 2026 Shengzhou Xinda Refrigeration Equipment Factory All Rights Reserved.