What's the difference between DL,DD and DJ series freezer air coolers?

  • Release time: 2026-09-02

What's the difference between DL,DD and DJ series freezer air coolers?

DL, DD and DJ air coolers are different in fin separation, temperature range and thawing compatibility under different refrigeration room conditions.

DL series air coolers are specially designed for high greenhouses between+12 C and 2 C, with standard blade separation of 4.0-4.5 mm to reduce the flow resistance in fresh agricultural products warehouses. This tight separation improves the heat exchange efficiency by 12% to 18%, and the load is greater than zero without serious frost accumulation. In the fruit and vegetable protection environment, when the relative humidity is kept below 85%RH, narrow fins can improve heat transfer.

DD series air coolers are suitable for the average temperature room from-2 C to-18 C, and the distance between wing plates is 4.5-6.0 mm, which can withstand frost blockage in frozen food warehouses. The field test data show that the specifications of this wing allow continuous operation for 6-10 hours, and then it needs to be thawed indoors at 80%RH. The wide groove can slow down the frost accumulation of DL unit by retaining frozen meat and seafood.

DJ series air coolers provide super freezing rooms from-18 C to-31 C, equipped with 6.0-9.0 mm blade separators, which are suitable for high frost and low temperature conditions. The actual project records show that DJ evaporator can reduce the frosting flow by 27% compared with DD model running below-25 C. The extra-wide groove can prevent the rapid freezing tunnel and the rapid blockage of the low-temperature drug warehouse.

Electrolysis is the standard configuration of DL, DD and DJ, while D series hydrolytic air cooler provides optional spray thawing for continuous operation facilities. Water thawing can shorten the duration of each cycle to 12-18 minutes, compared with 25-40 minutes of resistance thawing with the same refrigeration capacity. This alternative is suitable for production rooms that do not support long-term thawing downtime.

DL,DD and DJ air coolers support common refrigerants R22,R404A and R507A; DJ model also supports NH3 ammonia in large industrial refrigeration systems. According to the specification data of xindacool module, DJ unit compatible with ammonia needs improved heat exchange materials to resist chemical corrosion of fluid. If you switch to NH3 refrigerant in the low-temperature evaporator, you must update the material.

Wrong model selection will bring obvious operating losses to refrigeration projects. Using DL cooler indoors at-20 C, the defrosting frequency is increased every 2-3 hours, which increases the total energy consumption of the system by 35%. Mismatch of blade separation is one of the most common engineering mistakes when purchasing refrigeration equipment.

When selecting DL/DD/DJ air cooler, the buyer must first confirm that the room temperature is stable, select the corresponding series, calculate the required capacity according to the volume and heat load, and decide on the standard electric defrosting system or the upgraded D series water defrosting. The error of capacity calculation exceeding 15% will make the camera unable to reach the target temperature for actual operation.

For system pairing, the end user must combine the selected cooler with FNH,FNV or FNVT air-cooled condenser according to the total cooling load. The models of FNH/FNV side discharge and FNVT top discharge need to be adjusted according to the outdoor space and local maximum ambient temperature. Ambient temperature higher than 38°C will reduce the rated capacity of most air-cooled condensers by 18% to 22%.

FAQ
What kind of room temperature does DL series cooler support? The DL model is suitable for storage rooms between+-2 °C and-2 C..
What is the fin separation caused by DD series coolers? DD has 4.5-6.0 mm blade separation for frozen storage.
Does DJ cooler support ammonia refrigerant? DJ supports the anti-corrosion modification of NH3 and its exchange components.
Can hydrolysate be installed on DD device? DD can be upgraded to D-series hydrolysis version to obtain shorter cycle time.
How long is the electrolysis cycle of DD? The standard DD electrolytic cycle lasts for 25-40 minutes under normal humidity.
What are the risks of adjusting the fins incorrectly? Incorrect separation will lead to frost blockage and increase energy consumption.
Which coolers support FIN?

url: https://xindacool.com/news/478.html

Stable quality · Trustworthy

CONTACT US

Address: No. 866, Putian Avenue, Sanjiang Sub-district, Shengzhou City, Zhejiang Province 
Mobile phone: +86 13567599011
Landline: 0575-83268796 
Email:michelle@xindacool.com

Copyright © 2026 Shengzhou Xinda Refrigeration Equipment Factory All Rights Reserved.