Do DL, DD and DJ air coolers support R404A and R507A refrigerants in industrial refrigeration equipment?

DL,DD and DJ are compatible with R404A and R507A when they leave the factory, but the working pressure is different, so the system needs to be set according to the substances used.

R404A and R507A are widely used refrigerant mixtures in middle and low temperature freezing rooms. Both of them have similar thermodynamic characteristics, but they cannot be completely exchanged without adjusting the parameters. At the same evaporation temperature of refrigerating room, the saturation pressure of R507A is about 5% higher than that of R404A.

DL series tank air coolers support R404A and R507A in the working range of+−2 °C to 2 C.. The heat exchanger does not need to be structurally reformed; Only the overheating value of the expansion device of the refrigeration system needs to be adjusted. For these devices, the recommended overheating range is 5 K to 7 K..

DD series medium temperature air coolers also support these two refrigerants, and no special adjustment is needed in the range of-2 C to-18 C.. Under the working condition of-18 C, the evaporation pressure of R507A is 5% higher than that of R404A, so the pressure gauge reading will be different. When using R507A to load the system, you should not rely on R404A table to avoid adjustment errors.

url: https://xindacool.com/news/489.html

Stable quality · Trustworthy

CONTACT US

Address: No. 866, Putian Avenue, Sanjiang Sub-district, Shengzhou City, Zhejiang Province 
Mobile phone: +86 13567599011
Landline: 0575-83268796 
Email:michelle@xindacool.com

Copyright © 2026 Shengzhou Xinda Refrigeration Equipment Factory All Rights Reserved.